Sewer Pipe Sizing (MSIG/SPAN)
Ref: MSIG (Malaysian Sewerage Industry Guidelines) & SPAN UTG
Saved to this browser only. Sign in to sync across devices.
Q_design = PF × DWF + Infiltration
Ref: MSIG (Malaysian Sewerage Industry Guidelines) & SPAN UTG
DWF = PE × q / 86400 (L/s)
Dry Weather Flow
PF = 1 + 14 / (4 + √(PE/1000))
Harmon's Peak Factor
Q_full = (1/n) × A × R^(2/3) × S^(1/2)
Manning's full flow
Sewage Flow
Total PE served (residential: 1 PE per person)
MSIG standard: 225 L/person/day (domestic)
Typical 0.05 L/s per mm dia per km of sewer
Pipe Properties
Min 150mm (house), 200mm (public sewer)
Min 1:200 for 150mm, 1:250 for 200mm
uPVC/VC 0.011, Concrete 0.013
Disclaimer: This output is an engineering calculation aid only and does not constitute a final or endorsed design. All designs submitted to Malaysian authorities must be endorsed by a registered Professional Engineer (PE) under the Board of Engineers Malaysia (BEM) in accordance with the Registration of Engineers Act 1967.